Electronic Hookup Wire
Exruded Polytetrafluoroethylene
(PTFE) Insulation
Nominal .010” Wall
-65ºC to +200ºC
600 Volts. R.M.S. (working)
Meets UL Style 1213 except where noted.
For internal wiring of meters, panels and electronic equipment . Formerly "Mil-W-16878/4"
Military Voltage Rating | 600 volts. | |
Dielectric Voltage Withstand | 2000 Volts, Wet | |
Sine-wave Spark-Test Voltage | 3400 VAC. | |
Impulse Spark Test Voltage | 6500 V pulse-peak | |
Insulation Breakdown Voltage | > 6800 volts, peak. | |
IR: Insulation Resistance, wet | > 10000 megohm/100 mtr, metal to water bath at +20ºC | |
Nominal Dielectric Constant value | 2.04 | |
Flame Properties | Self extinguishing | |
Cold Bending for gauges 32 to 16 | Bends over a 1 inch mandrel while at -54ºC | |
Cold Bending for gauges 14 to 10 | Bends over a 2 inch mandrel while at -54ºC | |
Fungus | Fungus resistant | |
DOWNLOAD PDF NEMA HP-3 TYPE E. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
Standard basic insulation color numbers are: Black: 0, Brown: 1, Red: 2, Orange: 3, Yellow: 4, Green: 5, Blue: 6, Violet: 7, Gray: 8, White: 9. The insulation color code number, may be 1, 2 or 3 digits depending on the number or absence of stripes. The 1st number is color of Insulation, 2nd number is color of first stripe; 3rd number is color of the second stripe. Example: White wire(9) + Red stripe(2) + Black stripe(0) makes a color code number of “9-2-0”. That color number, "9-2-0" is appended to the part number. Sample part number might be "xxxxxx-xxx-9-2-0"
Download Color InformationGAUGE OF CONDUCTOR | 16 |
GAUGE OF STRANDS | 29 |
MAX RESISTANCE DC AT 20° C PER 1000 FEET | 4.52 |
MAX RESISTANCE DE AT 20 ° C PER KM | 15 |
NEMA SPEC HP3WIRE PART NUMBER | HP3-EXBJEx |
NOM. DIAM. STRANDED CONDUCTOR (INCHES) | 0.057 |
NOM. DIAM. STRANDED CONDUCTOR (MM) | 1.45 |
NOM. FINISHED WIRE DIAM. (INCHES) | 0.08 |
NOM. FINISHED WIRE DIAM. (MM) | 2.03 |
NOM. WEIGHT LBS. PER 1000 FEET | 11 |
NOM. WEIGHT KG/KM PER 1000 FEET | 16.4 |
NOT UL RECOGNIZED | 1 |
NUMBER OF STRANDS | 19.00 |
ROHS | Yes |