Single Conductors
Mil Spec UL AWM
Recognized Style 2343 or 2344 and CSA Certified AWM II A/B
National Wire & Cable Corp. manufactures a complete line of extra heavy duty multi-conductor control cables. Conductors are of tinned copper strand with .031” wall of polyvinylchloride primary insulation for use up to 105°C. Per MIL-W-16878/3, insulated for 3000 volts working voltage
Conductors are color coded using 10 standard basic colors, plus spiral tracers on white per MIL-STD-681.
All conductor are planetary cabled and contra-helically laid for optimum flexibility, with a Mylar tape serve over cable bundle. Shielded cables have a tinned copper braid overall, of 85-90% coverage per MIL-C-7078, and braid angles below 40° for easy pushback.
The outer jacket is black, abrasion-resistant 105°C vinyl meeting MIL-I-631 Type F. This material is self-extinguishing and fungus resistant. Neoprene to MIL-R-6855 Class 2 Grade 60 specifications also available on special for non-U.L. applications.
"Cables are U.L. STYLE 2343 or 2344, rated 80°C, and CSA CERTIFIED for 105°C U.L. and/or CSA Certification furnished only when requested."
Identical to National’s NW-Series Cables except offered as twisted pairs.
Insulated wires also meet Style 1015.
Insulation Breakdown Voltage | Greater than 12000 volts AC RMS, 60cps. | |
UL Voltage Rating | 600 volts RMS AC (appliance use) -- 2500 volts RMS AC (electronic use) | |
CSA Voltage Rating | 600 volts RMS AC (appliance use) | |
Military Voltage Rating | 3000 volts RMS | |
Capacitance | Nominal capacitance from a wire to all else in the cable ranges from 40 to 65 pf per ft. @ 1000 cps. dependent on gauge and position. | |
Insulation Leakage Res | 200 megohms/1000 ft. min. at 500 VDC from any conductor to all else in cable. | |
Sheath Leakage Res | 10 megohms/1000 ft. min. at 500 VDC form overall shield through sheath to outside world. | |
Usable Temp. Range | Suitable for continuous use from +105°C to -40°C. | |
Cold bending Capacity | All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing application consult the factory. | |
DOWNLOAD PDF for NWH & NWHC single cabled conductors. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
UNSHIELDED | Yes |
GAUGE OF CONDUCTOR | 18 |
JACKET WALL (INCHES) | 0.062 |
JACKET WALL (MM) | 1.6 |
NOM. CABLE DIAM. (INCHES) | 0.586 |
NOM. CABLE DIAM. (MM) | 14.9 |
NOM. WEIGHT LBS. PER 1000 FEET | 186 |
NOM. WEIGHT KG/KM PER 1000 FEET | 276 |
NUMBER OF CONDUCTORS | 12 |
OVERALL CONDUCTOR DIAM. (INCHES) | 0.11 |
OVERALL CONDUCTOR DIAM. (MM) | 2.8 |
ROHS | Yes |