U.L. AWM Style 1061
U/L Recognized Appliance Wiring Material
VW-1 Rated
80ºC Service
.009: Semi-Rigid Vinyl Insulation
300 Volt
Meets MIL-W-16878/1 and CSA AWM I A/B (previously
S-R PVC, T2) for 80º Service, except where noted.
Wires recognized by the Underwriters' Laboratories, Inc for operation in an air environment, U.L. File #E35793.
Agency Voltage Rating | 300 volts. | |
Factory Spark-Test Voltage | 3400 VAC. 100% of all wire is tested at this voltage. | |
Insulation Breakdown Voltage | > 5000 volts, peak. | |
IR: Insulation Resistance, wet | > 1500 megohm/100 mtr, metal to water bath at +20ºC | |
Nominal Dielectric Constant value | 4 | |
Flame Properties | Self extinguishing. Meets UL VW-1 | |
Fungus | Fungus resistant | |
DOWNLOAD PDF UL AWM Style 1061. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
Standard basic insulation color numbers are: Black: 0, Brown: 1, Red: 2, Orange: 3, Yellow: 4, Green: 5, Blue: 6, Violet: 7, Gray: 8, White: 9. The insulation color code number per MIL-STD-681, may be 1, 2 or 3 digits depending on the number or absence of stripes. The 1st number is color of Insulation, 2nd number is color of first stripe; 3rd number is color of the second stripe. Example: White wire(9) + Red stripe(2) + Black stripe(0) makes a color code number of "9-2-0". That color number, "9-2-0" is appended to the part number. Sample part number might be "xxxxxx-xxx-9-2-0"
Download Color InformationGAUGE OF CONDUCTOR | 26 |
GAUGE OF STRANDS | 26 |
MAX RESISTANCE DC AT 20° C PER 1000 FEET | 44.5 |
MAX RESISTANCE DE AT 20 ° C PER KM | 146 |
NOM. DIAM. STRANDED CONDUCTOR (INCHES) | 0.0159 |
NOM. DIAM. STRANDED CONDUCTOR (MM) | 0.404 |
NOM. FINISHED WIRE DIAM. (INCHES) | 0.036 |
NOM. FINISHED WIRE DIAM. (MM) | 0.914 |
NOM. WEIGHT LBS. PER 1000 FEET | 1.35 |
NOM. WEIGHT KG/KM PER 1000 FEET | 2.01 |
NUMBER OF STRANDS | 1.00 |