Single Conductors
Mil Spec UL AWM
Recognized Style 2343 or 2344 and CSA Certified AWM II A/B
National Wire & Cable Corp. manufactures a complete line of multiple conductor control cable. All conductors are stranded tinned copper with .015” wall of vinyl primary insulation for use up to 105°C per MIL-W-16878/2*. Insulated for 1000 volts working voltage. Color coded using 10 standard plus stripes on white per MIL-STD-681.
All conductors are planetary cabled and contra-helically laid for optimum flexibility, with a Mylar tape serve over cable bundle. Shielded cables have a tinned copper braid overall, of 90% coverage per MIL-C-7078 and braid angles below 40° for easy pushback
The outer jacket is black, abrasion-resistant 105°C vinyl meeting MIL-I-631 Type F. All materials are self-extinguishing and fungus resistant. Also available with Neoprene jacket as a custom product. Consult factory for details.
Insulated wires also meet U.L. Style 1007 or 1569 as appropriate for gauge.
Cables are U.L. STYLE 2343 or 2344, rated 80°C, and CSA CERTIFIED for 105°C.
U.L. and/or CSA certification furnished only when requested.
Insulation Breakdown Voltage | Greater than 5000 volts AC RMS, 60cps. | |
UL Voltage Rating | 300 volts RMS AC (appliance use) -- 600 volts RMS AC (electronic use) | |
CSA Voltage Rating | 300 volts RMS AC (appliance use) | |
Military Voltage Rating | 1000 volts RMS | |
Capacitance | Nominal capacitance from a wire to all else in the cable ranges from 40 to 65 pf., @ 1000 cps, dependent on gauge an position. | |
Insulation Leakage Res | 200 megohms/1000 ft. min. at 500 VDC from any conductor to all else in cable. | |
Sheath Leakage Res | 10 megohms/1000 ft. min. at 500 VDC form overall shield through sheath to outside world. | |
Usable Temp. Range | Suitable for continuous use from -40°C to +105°C. | |
Cold bending Capacity | All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing application consult the factory. | |
DOWNLOAD PDF for NW & NWC cabled single conductors. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
UNSHIELDED | Yes |
GAUGE OF CONDUCTOR | 22 |
JACKET WALL (INCHES) | 0.062 |
JACKET WALL (MM) | 1.6 |
NOM. CABLE DIAM. (INCHES) | 0.32 |
NOM. CABLE DIAM. (MM) | 8.1 |
NOM. WEIGHT LBS. PER 1000 FEET | 55 |
NOM. WEIGHT KG/KM PER 1000 FEET | 82 |
NUMBER OF CONDUCTORS | 7 |
OVERALL CONDUCTOR DIAM. (INCHES) | 0.064 |
OVERALL CONDUCTOR DIAM. (MM) | 1.6 |
ROHS | Yes |