NRW722J

Heavy Duty Multiple Conductor Control Cables

NW Series - Cabled Single Conductors - Unshielded and Overall Shielded (RoHS)

Single Conductors
Mil Spec UL AWM
Recognized Style 2343 or 2344 and CSA Certified AWM II A/B
National Wire & Cable Corp. manufactures a complete line of multiple conductor control cable. All conductors are stranded tinned copper with .015” wall of vinyl primary insulation for use up to 105°C per MIL-W-16878/2*. Insulated for 1000 volts working voltage. Color coded using 10 standard plus stripes on white per MIL-STD-681.
All conductors are planetary cabled and contra-helically laid for optimum flexibility, with a Mylar tape serve over cable bundle. Shielded cables have a tinned copper braid overall, of 90% coverage per MIL-C-7078 and braid angles below 40° for easy pushback
The outer jacket is black, abrasion-resistant 105°C vinyl meeting MIL-I-631 Type F. All materials are self-extinguishing and fungus resistant. Also available with Neoprene jacket as a custom product. Consult factory for details.
Insulated wires also meet U.L. Style 1007 or 1569 as appropriate for gauge.
Cables are U.L. STYLE 2343 or 2344, rated 80°C, and CSA CERTIFIED for 105°C.
U.L. and/or CSA certification furnished only when requested.

Specifications

Insulation Breakdown Voltage Greater than 5000 volts AC RMS, 60cps.
UL Voltage Rating 300 volts RMS AC (appliance use) -- 600 volts RMS AC (electronic use)
CSA Voltage Rating 300 volts RMS AC (appliance use)
Military Voltage Rating 1000 volts RMS
Capacitance Nominal capacitance from a wire to all else in the cable ranges from 40 to 65 pf., @ 1000 cps, dependent on gauge an position.
Insulation Leakage Res 200 megohms/1000 ft. min. at 500 VDC from any conductor to all else in cable.
Sheath Leakage Res 10 megohms/1000 ft. min. at 500 VDC form overall shield through sheath to outside world.
Usable Temp. Range Suitable for continuous use from -40°C to +105°C.
Cold bending Capacity All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing application consult the factory.

DOWNLOAD PDF for NW & NWC cabled single conductors. Also listed in the National Wire Printed Catalog.

RoHS products are listed with an "R" in the second position of the Part Number.

UNSHIELDEDYes
GAUGE OF CONDUCTOR22
JACKET WALL (INCHES)0.062
JACKET WALL (MM)1.6
NOM. CABLE DIAM. (INCHES)0.32
NOM. CABLE DIAM. (MM)8.1
NOM. WEIGHT LBS. PER 1000 FEET55
NOM. WEIGHT KG/KM PER 1000 FEET82
NUMBER OF CONDUCTORS7
OVERALL CONDUCTOR DIAM. (INCHES)0.064
OVERALL CONDUCTOR DIAM. (MM)1.6
ROHSYes
 