National Wire & Cable Corporation manufactures a complete line of MINIATURE low voltage signal and control cable. Available as cabled pairs or cabled singles, with optional overall shield. Conductors are stranded tinned copper with .010” wall of vinyl primary insulation for use up to 105°C. per MIL-W-16878/1.
Insulated for 600 volts working voltage. (Also meets U.L. AWM Type 1061; 300 volt, 80°C.) All are coded using 10 standard colors plus stripes on white per MIL-STD-681.
All conductors are planetary cabled and contra-helically laid for optimum flexibility, with a Mylar tape barrier undershields. Shielded cables have a tinned copper braid overall, of 85-90% coverage per MIL-C-7078;and braid angles below 40° for easy pushback.
The outer jacket is black abrasion-resistant 105°C. vinyl meeting MIL-I-631 Type F. All materials are self-extinguishing and fungus-resistant. All items are U.L. STYLE 2343 COMPUTER CABLE; rated 80°C (Higher temp. ratings apply for any non-U.L. service). Meets E.I.A. Standard RS-232 for 18-24 gauges.
*CSA certification furnished only when requested.
Standard Putups: 500 and 1000 ft. No-deposit reels.
Insulation Breakdown Voltage | Greater than 3400 volts AC RMS, 60cps. | |
Capacitance | Nominal capacitance from a wire to all else in a cable ranges from 45 to 70 pf/ft at 1 kc, depending on gauge and position. | |
Insulation Leakage | 200 megohms/1000 feet minimum @ 500 VDC form conductor to all else in cable. | |
Sheath Leakage | 10 megohms/1000 feet minimum @ 500 VDC from shield or conductor group through sheath to ground. | |
Temperature Range | Suitable for continuous use from -40°C to +105°C. (U.L. Service limited to +80°C) | |
Bending Characteristics | All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing applications consult the factory. | |
DOWNLOAD PDF for NX Cable. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
UNSHIELDED | Yes |
GAUGE OF CONDUCTOR | 20 |
JACKET WALL (INCHES) | 0.062 |
JACKET WALL (MM) | 1.6 |
NOM. CABLE DIAM. (INCHES) | 0.302 |
NOM. CABLE DIAM. (MM) | 7.7 |
NOM. WEIGHT LBS. PER 1000 FEET | 61 |
NOM. WEIGHT KG/KM PER 1000 FEET | 90 |
NUMBER OF CONDUCTORS | 7 |
OVERALL CONDUCTOR DIAM. (INCHES) | 0.062 |
OVERALL CONDUCTOR DIAM. (MM) | 1.5 |